National Institutes of Health
Industrial Noise, Measurement, Mitigation, Noise Control, Regulatory Compliance
Industrial Noise, Measurement, Mitigation, Noise Control, Regulatory Compliance
Measurement, Mitigation, Public Interaction, Railway Noise, Regulatory Compliance
Highway Noise, Measurement, Mitigation, Public Interaction, Regulatory Compliance
Industrial Noise, Noise Control, Room Acoustics, Sound Transmission, Structural Dynamics, Vibration Isolation
Highway Noise, Measurement
Aviation Noise, Shock Wave
Structural Dynamics
Noise Control
Noise Control
Noise Control, Sound Transmission, Vibration Isolation
Structural Dynamics
Noise Control, Room Acoustics, Vibration Isolation
Product Development, Vibration Isolation
Noise Control, Vibration Isolation
Structural Dynamics
Noise Control, Room Acoustics, Sound Transmission, Structural Dynamics, Vibration Isolation
Noise Control, Room Acoustics, Sound Transmission, Structural Dynamics, Vibration Isolation
Noise Control, Sound Transmission
Sound Transmission
Sound Transmission
Sound Transmission
Noise Control, Room Acoustics, Sound Transmission
Noise Control, Room Acoustics
Noise Control, Room Acoustics, Sound Transmission, Vibration Isolation
Structural Dynamics
Noise Control, Sound Transmission, Vibration Isolation
Noise Control, Vibration Isolation
Noise Control, Room Acoustics, Sound Transmission, Vibration Isolation
Room Acoustics
Structural Dynamics
Industrial Noise, Measurement, Mitigation, Noise Control, Regulatory Compliance
Location: Bethesda, Maryland
Employer: Colin Gordon
Environmental study for campus wide source identification for 260- acre facility requiring evaluation of over 500 noise sources through measurements and modeling; along with community noise measurements, Community noise and mitigation recommendations.
Measurement, Mitigation, Public Interaction, Railway Noise, Regulatory Compliance
Location: Anaheim, California
Employer: Acentech
Environmental study and design services for 12,000 ft railway corridor, including modeling, for “absorptive” barrier to reduce noise.
Highway Noise, Measurement, Mitigation, Public Interaction, Regulatory Compliance
Location: San Jose, California
Employer: Acentech
Post-construction community noise study of mitigation alternatives involving comparisons of multiple technologies and approaches for abating as-measured noise levels.
Industrial Noise, Noise Control, Room Acoustics, Sound Transmission, Structural Dynamics, Vibration Isolation
Location: Edmonton, Alberta
Employer: Colin Gordon
Comprehensive design services including architectural acoustics; mechanical noise control (interior and exterior) and vibration isolation; and structural floor vibration.
Highway Noise, Measurement
Location: Victoria, B.C., Canada
Employer: British Columbia Ministry of Transportation & Highways
Sponsored graduate-thesis work that included measurements of insertion loss for three highway noise-control barriers, all earthen berms, and contributions to the preparation of an organizational design guide.
Aviation Noise, Shock Wave
Location: Point Mugu, California
Employer: Acentech
Environmental Assessment of F-22 supersonic operations over water
Structural Dynamics
Location: Las Vegas, Nevada
Employer: Swallow Acoustical Consultants
Designed and validated tuned mass dampers (TMDs), installed beneath on an exterior cantilevered concourse, which reduced footfall vibration amplitudes by 80%. The facility houses 20,000 people for events including basketball, boxing, ice hockey and concerts
Noise Control
Location: Pudong, Peoples Republic of China
Employer: Colin Gordon
Measurements of noise and analysis of methods to reduce cleanroom noise.
Noise Control
Location: Ocotillo, Arizona
Employer: Colin Gordon
Measurement survey of noise within fabrication areas and associated equipment chases within cleanroom.
Noise Control, Sound Transmission, Vibration Isolation
Location: Regina, Saskatchewan, Canada
Employer: Pinchin
Provided measurements and analysis to document the extent to which noise within 4th floor office spaces is compromised by a poorly vibration isolated chiller in a 5th floor mechanical room. Provided recommendations for design improvements.
Structural Dynamics
Location: Rio Rancho, New Mexico
Employer: Colin Gordon
Measurement survey of vibration within fabrication and sub-fabrication areas within cleanroom
Noise Control, Room Acoustics, Vibration Isolation
Location: Leixlip, Ireland
Employer: Colin Gordon
Comprehensive design services including architectural acoustics; mechanical noise control and vibration isolation within fabrication facility’s cleanrooms.
Product Development, Vibration Isolation
Location: Aloha, Oregon
Employer: Colin Gordon
Custom design services of dedicated tool vibration response test facility to document sensitivity of TEL P-12XL probe tester with resulting reductions of facility design costs. Controlled testing of induced vibrations at micron scales.
Noise Control, Vibration Isolation
Location: Taiwan
Employer: Colin Gordon
Design services for new 300 mm wafer fabrication facility
Structural Dynamics
Location: Orlando, Florida
Employer: Acentech
Measurements to characterize existing structural floor mobility within cleanroom and potential for self-induced vibration errors
Noise Control, Room Acoustics, Sound Transmission, Structural Dynamics, Vibration Isolation
Location: Inuvik, Northwest Territories, Canada
Employer: HFP
Comprehensive design services including architectural acoustics; mechanical noise control and vibration isolation; and structural floor vibration.
Noise Control, Room Acoustics, Sound Transmission, Structural Dynamics, Vibration Isolation
Location: Palo Alto, California
Employer: Colin Gordon
Comprehensive design services including architectural acoustics; mechanical noise control (interior and exterior) and vibration isolation; and structural floor vibration.
Noise Control, Sound Transmission
Location: London, England
Employer: Colin Gordon
Infrasonic Noise Evaluation
Sound Transmission
Location: Washington, D.C.
Employer: Colin Gordon
Analysis and reporting of Noise Isolation Class (NIC) of doors and partitions to assess contractual compliance.
Sound Transmission
Location: Auckland, New Zealand
Employer: URS
Recommendations to Papakura District Council for a program of residential sound insulation at a general aviation airport with historic 1950s vintage “warbird” jet fighters.
Sound Transmission
Location: Indianapolis, Illinois
Employer: Acentech
Residential Sound Insulation Program. Measured sound transmission of aircraft noise within approximately 160 single family dwellings.
Noise Control, Room Acoustics, Sound Transmission
Location: Arden, North Carolina
Employer: Innova Global
Provided LEED credit design review for acoustics of administration/control/maintenance building.
Noise Control, Room Acoustics
Location: Pickering, Ontario
Employer: Pinchin
Provided noise measurements and recommendations to reduce noise levels within a facility control room.
Noise Control, Room Acoustics, Sound Transmission, Vibration Isolation
Location: Tempe, Arizona
Employer: Colin Gordon
Comprehensive design services including specification of mechanical noise control for two gas turbines; 2000-cooling ton chillers; and operators’ room
Structural Dynamics
Location: Houston, Texas
Employer: HFP
Design of medical tower including floor vibration studies for 13th floor of building for a magnetic resonance imaging (MRI) suite.
Noise Control, Sound Transmission, Vibration Isolation
Location: Manhattan, New York
Employer: Wilson Ihrig
Atop a mixed-use building, the rooftop cooling systems, connected to a ground-level magnetic resonance imaging (MRI) installation, caused complaints from the residents within a penthouse condominium. Noise and vibration measurements were made to compare levels to the provisions of Local Law 113 Noise Code along with recommendations to mitigate the problematic levels.
Noise Control, Vibration Isolation
Location: Calgary, Alberta, Canada
Employer: TBC
Post-installation measurements of mechanical system noise and vibration in order to arrive at an engineered noise-control solution for newly installed air handlers and transformers, along with evaluation of performance of industrial-scale silencers.
Noise Control, Room Acoustics, Sound Transmission, Vibration Isolation
Location: Calgary, Alberta, Canada
Employer: HFP
Comprehensive design services including architectural acoustics; and mechanical noise control and vibration isolation.
Room Acoustics
Location: Vancouver, B.C., Canada
Employer: Natural Sciences & Engineering Research Council of Canada, Professor Murray Hodgson
Natural Sciences & Engineering Research Council of Canada, Room Acoustics Study, Professor Murray Hodgson. Measurements of reverberation time and sound propagation in comparison to modeling results for thirteen rooms where speech comprehension and/or music appreciation were of concern, including locations at the University of British Columbia and the Provincial Court of British Columbia.
Structural Dynamics
Location: Atlanta, Georgia
Employer: Wilson Ihrig
Supported analysis of excessive footfall vibration on a pedestrian footbridge through a review of vibration measurement data and discussion of design improvements